How to operate the pulse dust collector when it stops The correct operation of the pulse dust collector is very important, as it will not only affect the dust removal effect, but also shorten the service life of the pulse dust collector. We have learned about the correct operation of the pulse dust collector, and it is no exception when shutting down. Let's take a closer look at it today; 1. Turn off the automatic cleaning mode. Before the equipment cools down, the dust bag of all the compartments is circulated twice. However, if you know the time of the shutdown in advance, you should take measures to stop the cleaning. If the shutdown does not exceed twenty-four hours, do not remove the dust, so that the dust on the dust bag will act as a dust powder when restarting. 2. When the inlet temperature of the precipitator drops to 125 degrees, the auxiliary fuel burner is used to stabilize the temperature of the gas until the coal fire is extinguished. 3. Continue to operate the induced draft fan for one hour to remove the acid gas remaining in all the compartments of the precipitator, and then stop the induced draft fan operation. 4. The ash conveying system continues to operate, and the ash bucket should be kept heated during the entire shutdown process until all the ash in the ash hopper is emptied. 5. Open the bypass valve of the dust collector. 6. Close the outlet valve on the precipitator. 7. Close the inlet butterfly valve. However, it should be noted that the inlet butterfly valve should not be closed if the ash system is still in operation. Because this will cause excessive pressure on the dust bag, the dust on the dust bag will be pulled off, so that the dust bag will get wet. 8. The dust collector should be kept in the bypass state until it is ready to resume online, and then press “General Startup Method†to execute. Sunshade Net,White Agriculture Shade Cloth,Air Filter Aluminum Foil Net,Fence Balcony Privacy Netting Changzhou Green Nets Co.,Ltd. , https://www.gnshadenet.com